User Interface
- The speed of reading MDL and CAD files has been improved.
- When a program is open additional file types can be opened by drag & drop (.act, .nom, .aat, .des, .apt, .chr). This is in addition to the previously supported CAD file types.
- The Graphics Options dialog now supports customization of vector dimensions and anti-aliasing (smoothing). The CAD View settings have also been organized into a new dialog tab.
- Visualization of group items in the Display Options dialog has been improved when Nominals, Actuals, CAD, or Probe are turned off or on.
- The new Select Sensor dialog has additional quality-of-life improvements.
- The Graphics window is more responsive when there are many touch points or large point clouds.
- The option to Display Collision Zones has been added to the Probe ribbon menu. This was previously a setting in the System Configuration dialog.
- The Curve Scan Dialog can be opened directly from the ribbon menu while in MES-CAD mode. The OnCurve method is used by default for analog and laser probes. This bypasses the small window with 4 buttons.
- Opening a program from the File ribbon menu now uses a dialog to browse for the program’s .bdm file. A similar ability has been added to the Quick Menu.
- The Calibration commands have been grouped in the Probe ribbon menu.
- The Confetti Settings ribbon menu button has been moved from the Graphics tab to the Report tab.
- Improved user experience for the Measure Curve dialog.
- Improved detection of invalid characters in the Database Connection dialogs.
- CAPPS-DMIS: Improved user experience for the manual Measure dialogs.
DMIS & Program Window
- Temperature compensation now fully supports Fahrenheit. The temperature unit is recorded into DMIS.
- New commands have been added for nominal curves and surfaces that allow access to the location and normal vector of a specific touch-point. This was previously only possible for actual curves and surfaces.
- A new command was added to run an external script file and wait for completion.
- CAPPS-NC: The Recall Alignment dialog allows editing work offset alignments, making offline programming easier.
Reporting
- Image Resolution has been added to the Print Settings dialog to allow the quality (and size) of images created for reports to be increased. These high-definition images look better when zooming in to a report saved to PDF, for example.
- Added support for two more GD&T Datum scenarios: {plane, perpendicular cylinder, plane} and {plane, perpendicular cylinder, point-reducible feature}.
- All types of Distance templates now have their connection lines drawn parallel to the two features, instead of only in the screen’s X and Y axis.
- The Form & Profile dialog has a new Use Bestfitting option to control calculating profiles of patterns, curves, and surfaces. This change provides the flexibility to disable the best fit when it is not needed.
- Circular and Total Runout are now available for Cones.
- The location that Composite True Position is reported at can be customized.
Feature Construction
- The Construct Curve dialog has a new Digitize action. This includes the generation and execution of new CAPPS/DIGITCURVE DMIS commands.
- Curves can be constructed by intersecting a plane with a surface.
- Planes can be constructed from two lines (using their endpoints) or one point and one line.
- A circle can be constructed by intersecting a cylinder and a sphere.
Machine Interfaces
- CAPPS-NC: A new Tool Settings popup was added to the Probe Builder.
- This groups the CNC-specific settings together.
- Can specify the NC Filename.
- Can specify if running from the tool bottom or center.
- CAPPS-NC: Added support for Mitsubishi controllers.
- CAPPS-NC: Added large program support for Fidia controllers.
- CAPPS-NC: FOCAS Data I/O dialog now:
- Allows multiple files to be sent to the controller together.
- Remembers the last used programs folder.
Laser & Point Clouds
- The Probe Builder now allows rotating laser models. This requires the latest probe database.
- Improved accuracy of the laser calibration. Now scanning is done in one direction instead of going back and forth.
- Extracting spheres from point clouds now supports using filters.
- Improved the accuracy of Angle and Edge points extracted from point clouds.
Simulation
- Table rotation measurement has been enabled for 5-axis tables, indexable probe heads, and when optimum probe selection is active.
Probe Calibration
- Blum probes are now supported.
- Renishaw probe modules OM/RMP40/60 are now fully supported. These probes support stacking many modules.